
Add to Cart
3nh Benchtop Plastic, Film, Glass, LCD Panel, Touch Screen Spectrophotometer YS6002 Haze Measurement Device
Brief Introduction
3nh Benchtop Plastic, Film, Glass, LCD Panel, Touch Screen Spectrophotometer Haze Measurement Device is developed by 3nh independently with proprietary intellectua property. This machine adopts transmittance optical geometry d/0 (diffused illumination, 0-degree viewing angle) which confirms to CIE 15 standard. It can also realized the the optical geometry 0/0 (parallel illumination, 0-degree viewing angle).
3nh Benchtop Plastic, Film, Glass, LCD Panel, Touch Screen Spectrophotometer Haze Measurement Device uses 360~780nm composite full spectrum LED light source (which is closed to the spectrum of D65), and it can realize intervals 10nm spectrum by precision concave grating and 256 Image Element CMOS Sensor. Accordance with industry-standard, YS6002 will give the accuracy result for the measurement of haze, transmittance, chromaticity, color difference, WI, YI, Pt-Co Index and Gardner index etc. It is widely used in the field of glass processing, plastic processing, film manufacturing, display screen processing and packaging industry, liquid pharmaceutical analysis, laboratory etc.
Main Features
Technical Details
Model | YS6002 |
Transmittance:d/0 (diffused illumination, 0-degree viewing angle); | |
Optical Geometry | similar to CIE15 standard 0/0(parallel illumination, 0-degree viewing angle); |
Confirms to the standard of ASTM D1003/1044, CIE No.15, GB/T 3978, GB | |
2893, GB/T 18833, ASTM E308, DIN5033 Teil7 | |
wildly used in the field of glass processing, plastic processing, film | |
Application | manufacturing, display screen processing and packaging industry, liquid |
pharmaceutical analysis, laboratory etc. | |
Intergrating Sphere Size | Φ154mm |
Light Source | 360~780nm Combined LED Lamp |
Spectral Separation | Concave-Grating |
Device | |
Detector | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360~780nm |
Wavelength Pitch | 10nm |
Half Bandwidth | 10nm |
Reflectance Range | 0~200% |
Measurement Aperture | Transmittance: Φ25.4mm |
Color Spaces | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Formulas | |
Haze (ASTM D1003/1044),transmittance rate T, | |
Other Colorimetric Data | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
TI(ASTM E313,CIE/ISO), | |
Mt(Matamerism Index ), | |
Color Strength, Staining fastness,Color Strength, Opacity, | |
Pt-Co index and Gardner index | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Display Data | Spectral/Values, Chromaticity Values, Color Difference Values/Graph,Color |
Diagram, Color Simulation, Pass/ Fall Result, Color Offset | |
Measurement Time | About 1.5s |
Spectral transmittance: for test transmission reference white within ΔE*ab | |
Repeatability | 0.05% (400~700nm: within 0.04%); |
Chromaticity Data: Φ25.4mm,within ΔE*ab 0.03 (after do warm-up and | |
calibration, it is the average value to measure transmission reference white | |
plate for 30 times at 5 second intervals) | |
Inter-instrument | Φ25.4mm,within ΔE*ab 0.15 (average value for 5 pcs standard transmittance |
Agreement | color plates measurement ) |
Size | 370X300X200mm(L*W*H) |
Weight | About 9.6kg |
Power | DC 24V,3A Power Adapter |
Illuminant Life Span | 5 years, more than 3,000,000 times measurement |
Screen | 7-inch TFT Capacity Touch Screen Display |
Interface | USB,Printing Port |
Storage | Standard:5000; Sample:20000 |
Language | Simplified Chinese, Traditional Chinese, English |
Working Temperature | 0~40℃(32~104°F) |
Storage Temperature | -20~50℃(-4~122°F) |
Power Adapter, User Manual, QC software(please download from website), | |
Standard Accessory | USB cable, reflectance white and black board, transmittance black board, |
25.4mm aperture, transmissive test component | |
Optional Accessory | Miniature- printer |
Note:The specifications are subject to change without notice. |
Pictures
Applicable Industries
3nh Benchtop Plastic, Film, Glass, LCD Panel, Touch Screen Spectrophotometer Haze Measurement Device is widely used in the field of glass processing, plastic processing, film manufacturing, display screen processing and packaging industry, liquid pharmaceutical analysis, laboratory etc.
FAQ
1: Q: Is your company accept customization?
A: We accept OEM/ ODM. Any color and any logo is welcome if placed at least 10pcs.
2: Q:Does your products have warranty?
A: YES, We offer 1 year warranty. Our policy: Is there any quality problem, First, send the defective machine to us and you bear the freight. Second, we send back to you free after fixed.
3: Q: After an order placed, when to deliver?
A: It depends on whether we are in stock or not. If we are, generally we can arrange shipment in 1 days after payment. If not, it will be decided by factory production.
4: Q: How to place an order?
A: a: send us an inquiry.
b: confirm your wanted products
c: confirm the price and freight and other details
d: finish the payment
e: we arrange the shipment
f: you got your products
Thank you very much and very best regards,
Suzie Xia
International Sales Dept.
--------------------------------------------------------------------------------
Shenzhen ThreeNH Technology Co., Ltd
Add: 4/F, Building 8, Nangang Second Industry Zone, Xili, Nanshan District, Shenzhen, 518055 China.
Tel: 0086-755-27198826 Ext: 601
Fax: 0086-755-27190609
Mobile: 0086-13510878132
Email: y@3nh.com
Skype: y@3nh.com
WhatsApp/Wechat: 86-15019429968
Website: www.3nh.com/en