Add to Cart
3NH Benchtop Spectrophotometer YS6010 High Accurate Versatile color measuring Instrument
Brief Introduction
YS6010 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments such as paints, inks, textiles, garments, printing and dyeing etc industries for color transfer and quality control. It can test Transmission Sample and Liquid, Powder, Solid Sample too.
Product Highlights
Never Settle--Choose The Professional Spectrophotometer
Plastic Sample
Reflection Measurement: d/8°, De:8° Structure (Diffuse Backlight, 8°Direction) Conforms To 1s07724/1 CIE, ASTM, DIN AND JIS Standards
Transmission Sample
Transmission Measurement Using d/0°(Diffuse Illumination 0°Direction Reception) In Accordance With ISO, CIE, ASTM AND DIN Standards
Liquid, Powder, Solid Sample Measurement
360~780nm Band Test, Professional Uv Sample Measurement, Consistently And Accurately Display Sample Chromaticity Value, Spectral Curve/Data, Color Bias.
Measuring Aperture
Automatic Identification Of Aperture, 25.4/15/8/4mm Four Apertures Can Be Switched At The Same Time, Taking Into Account The Special Needs Of Customers.
Main Features
Specification
Model | YS6010 Benchtop Spectrophotometer |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflectance: Φ30 mm/Φ25.4 mm; Φ10 mm/Φ8 mm; Φ6 mm/Φ4 mm |
Transmittance: Φ30 mm/Φ25.4 mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN |
Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter) |
Other Colorimetric Index | WI(ASTM E313, CIE/ISO, AATCC, Hunter), |
YI(ASTM D1925, ASTM 313),TI(ASTM E313, CIE/ISO), | |
Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, Cobalt platinum index, Gardner, 8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) |
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) | |
Spectral transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.04%) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15(Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Measurement Mode | Single Measurement, Average Measurement |
Locating Method | Camera View Finder Locating |
Power | AC 24V, 2A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | English, Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, White and Black Calibration Cavity, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber. |
Optional Accessory | Micro Printer, Transmission test fixture component, Inspector Green Board |
Notes: The specifications are subject to change without notice. |
More Pictures
Applications
Paint Matching Spectrophotometer YS6010 is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
Why use a colorimeter
When people observe the color of a product with the naked eye, the color information of the product can only be described in an abstract language. This is a certain inconvenience for industrial color communication. Therefore, in order to better detect the color and improve the color quality of industrial products, industrial production now uses precision colorimeter to measure the color information of the product. The purpose is to quantify the abstract color into specific color data, so whether it is detection or analysis or communication has become easier.
Advantages of precision colorimeter measurements
People's perception of monochrome changes with the background, the illumination source, and the emotion of the color measurer itself. These factors completely affect the accuracy of the results of color measurement, and people began to use precision colorimeter in order to improve the correctness and stability of product measurement. Precision colorimeter has the same sensitivity as the human eye box, but as the precision colorimeter uses the same standard light source and lighting environment to measure, the color information measured by both the indoor and outdoor, day and night, and the operator is the same. This makes the measurement simple and accurate and free from subjective factors and external environment.
In addition, the precision color difference meter can completely reveal the subtle chromatic aberration problem that is difficult to be discovered by the human eye. The actual difference between the two colors is almost the same as that of the human eye. However, this color difference still exists. In the industry where color accuracy is not high, these subtle chromatic aberrations may not have much impact, but in the industry where color quality is strictly required, such subtle chromatic aberration can be said to be fatal. The precision colorimeter can perfectly reveal the sharp color difference. Since the precision colorimeter is used to measure the result to the operator in digital form, so comparing the color digital information between the two products makes it easy to find subtle color changes. Controlling the color details in production is inseparable from precision colorimeter.
Shenzhen ThreeNH Technology Co., Ltd
Add: 4/F, Building 8, Nangang Second Industry Zone, Xili, Nanshan District, Shenzhen, 518055 China.
Tel: 0086-755-27198826 Ext: 639
Fax: 0086-755-27190609
Mobile: 0086-138 2314 1801
Email: shayneshui@3nh.com
WhatsApp/Wechat: 86-138 2314 1801
Website: www.threenh.com